Fast and sensitive detector for hydrogen detection

Scientists have succeeded in developing an extremely fast hydrogen detector capable of detecting hydrogen gas in concentrations below one percent, in less than seven seconds. In addition, the detector is capable of detecting hydrogen gas at levels of hundreds of parts per million within sixty seconds and at room temperature.

Toyota's right-hand fuel cell presented at its exhibition in New York in 2014. Photo: Joseph Brent.
Toyota's hydrogen fuel cell, 2014. Hydrogen gas is considered a next-generation environmentally friendly energy source. At the same time, hydrogen is a flammable gas that can cause an explosion, even when exposed to a tiny spark, hence the importance of detectors capable of quickly locating the odorless and colorless hydrogen gas. Photo: Joseph Brent.

[Translation by Dr. Nachmani Moshe]

Researchers from a university in Korea (KAIST) succeeded in developing an extremely fast hydrogen detector capable of detecting hydrogen gas in concentrations below one percent, in less than seven seconds. In addition, the detector is capable of detecting hydrogen gas at levels of several hundred parts per million (ppm) within sixty seconds and at room temperature. The detector itself is based on an array of palladium nanowires on the surface of which is a layer of 'metallic organoframework' (MOFs).

Hydrogen gas is considered an environmentally friendly energy source of the next generation. At the same time, hydrogen is a flammable gas that can cause an explosion, even when exposed to a tiny spark. In terms of safety, the lowest explosion threshold for hydrogen gas is set at 4% by volume, so detectors should detect the odorless, colorless hydrogen molecule quickly. It is reflected in guidelines recently formulated by the US Department of Energy. According to these guidelines, a hydrogen detector should detect a level of 1% (by volume) hydrogen gas in the air in less than sixty seconds in order to achieve appropriate response times.

Palladium nanowires coated with an organometallic chassis enable accurate and rapid detection of hydrogen molecules trapped between the pores formed in the system [courtesy of KAIST]
Palladium nanowires coated with an organometallic chassis enable accurate and rapid detection of hydrogen molecules trapped between the pores formed in the system [courtesy of KAIST]
In order to overcome the limitations of palladium-based hydrogen detectors, the researchers placed a MOF layer on the outer surface of a palladium nanowire array. The palladium nanowires were simply coated with an additional layer of a zeolitic imidazole framework (ZIF-8) composed of zinc ions and organic ligands. In view of the fact that the ZIF-8 type chassis is a highly porous material consisting of a number of micro-holes with sizes of 0.34 and 1.16 nm, the hydrogen gas, which has a diameter of 0.289 nm, can easily penetrate into the chassis membrane, while molecules larger than 0.34 nm are filtered out and not penetrating into the chassis membrane. Therefore, the ZIF-8 type filter located on the palladium nanowires allows the penetration of mainly hydrogen molecules, a result that gives rise to an acceleration of at least 20 times the reaction speed and sensing of hydrogen, compared to existing detectors.

The researchers hope that this extremely fast hydrogen detector could be useful in preventing explosion incidents caused by leaking hydrogen gas. In addition, the researchers hope that similar systems will be able to detect other harmful gases in the air accurately and quickly using this type of nanofiltration. The research findings have long been published in the scientific journal Applied Materials and Interfaces.

The news about the study

Article Summary

2 comments

Leave a Reply

Email will not be published. Required fields are marked *

This site uses Akismet to filter spam comments. More details about how the information from your response will be processed.